Engineered for Safety

We knew that there must be a safer way to retrieve a clot from the brain. The answer was already there. We leveraged the Comaneci technology and created the adjustable clot retriever. 

Aharon Friedman
Braiding Department Manager
Senior Engineer

Engineered for Safety

Controllability

  • Adjust diameter to overcome excessive resistance during retrieval

  • Incremental control

  • Adjustable RF

Delivery Profile

  • Deliver larger devices through smaller microcatheters

Max OD         9mm        6mm        3mm        2.5mm

Tiger              0.021”      0.021”     0.017”       0.013”

Competitor     NA           0.027”     0.021”       NA

Braided Design

  • Single piece shaft and stent reduces risk of detachment

  • High vessel compliance

  • “J” Shaped Soft Tip

Visibility

  • 100% radiopaque wires provide realtime feedback

To receive the webinar recording, please fill in the form below:

Tigertriever and Comaneci Webinar:

To receive the webinar recording, please fill in the form below:

The webinar is in Spanish

Tigertriever Webinar:

To receive the webinar recording, please fill in the form below:

 

 Tigertriever:

 

Net Length: 32 mm    

Compatibility: 0.021” ID microcatheter

Diameter: 1.5 - 6 mm

Europ/Asia Cat. Number: TRPP3155

Canada Cat. Number: TRP5155

Closed

4.5 mm

Open

4.5 mm

 Tigertriever 17:

 

Net Length: 23 mm    

Compatibility: 0.017” ID microcatheter

Diameter: 0.5 - 3 mm

Europ/Asia Cat. Number: TRPP3166

Canada Cat. Number: TRP5166

Tigertriever 13:

 

Net Length: 20.5 mm    

Compatibility: 0.016”/ 0.013” ID microcatheter

Diameter: 0.5 - 2.5 mm

Europ/Asia Cat. Number: TRPP3144

Canada Cat. Number: TRP5144

 Tigertriever XL:

 

Net Length: 53 mm    

Compatibility: 0.021” ID microcatheter

Diameter: 1.5 - 9 mm

Europ/Asia Cat. Number: TRPP3133

Case Studies

Example case 1#

71 year old female

MCA & ACA occlusion treated with Tigertriever

Images courtesy of: Prof. Rene Chapot, Alfried Krupp Krankenhaus, Essen, Germany

Pre

Post

Tiger - 1 pass MCA

Tiger - 1 pass ACA

Retrieved clots (MCA and ACA)

 

Example case 2#

74 year old male 

MCA occlusion treated with Tigertriever

Images courtesy of: Prof. Rene Chapot, Alfried Krupp Krankenhaus, Essen, Germany

Pre

Tigertriever

at MCA/ICA bifurcation

Post

Tiger - 1 pass MCA

TIGERTRIEVER

Adjustable Clot Retriever

T

Rapid Medical

Carmel Building P.O.B. 337

Yokneam, 20692 ISRAEL

Tel: +972-72-250-3331

Fax: +972-72-250-3332

© 2020 by Rapid Medical

  • Linkedin-Rapid Medical
  • Twitter_Rapid Medical